Ultrasonic Testing of Concrete Structures Using Indirect Transmission

CODEN: JTEVAB

Abstract

Laboratory studies and computer simulation were used to develop a procedure for the interpretation of the results of nondestructive testing of concrete structures using the indirect transmission method. The results of the laboratory studies indicate a 10-cm spacing is best for making ultrasonic pulse measurements. A new method of calculating the velocity of the pulse is presented. The method enables concrete quality to be evaluated over short distances rather than the existing method which gives a mean velocity over an extended distance. The method can thus determine the extent of delamination of concrete at a specific location. The laboratory analyses verified using computer simulations show the effect of concrete heterogeneity on the detection of variation in concrete quality. Ultrasonic pulse velocities have a coefficient of variation of about 2 %.

Author Information

Stergiopoulou, Christina
Department of Civil and Environmental Engineering, University of Maryland, College Park, MD
McCuen, Richard
Department of Civil and Environmental Engineering, University of Maryland, College Park, MD
Aggour, M.
Department of Civil and Environmental Engineering, University of Maryland, College Park, MD
Pages: 8
Price: $25.00
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Stock #: JTE101158
ISSN: 0090-3973
DOI: 10.1520/JTE101158