Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable D4566-05E01 ASTM|D4566-05E01|en-US Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable Standard new BOS Vol. 10.02 Committee D09
$ 119.00 In stock

Significance and Use

Electrical tests, properly interpreted, provide information with regard to the electrical properties of the insulation. The electrical test values give an indication as to how the insulation will perform under conditions similar to those observed in the tests. Electrical tests may provide data for research and development, engineering design, quality control, and acceptance or rejection under specifications.

Scope

1.1 These test methods cover procedures for electrical testing of thermoplastic insulations and jackets used on telecommunications wire and cable and for the testing of electrical characteristics of completed products. To determine the procedure to be used on the particular insulation or jacket compound, or on the end product, reference should be made to the specification for the product.

1.2 The test methods appear in the following sections of this standard:

1.3 The values stated in inch-pound units are to be regarded as the standard. SI units are for information only.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Sections and .

1.4 In-process electrical tests are used primarily as process control tools in an attempt to minimize the number and magnitude of problems detected at final test of completed cable.

1.5 Electrical tests of completed wire and cable may include verification of some or all of the properties in accordance with Sections through .