You are being redirected because this document is part of your ASTM Compass® subscription.
    This document is part of your ASTM Compass® subscription.

    Volume 39, Issue 5 (September 2016)

    Laboratory Investigation of the Seepage Induced Response of Granular Soils Under Static and Cyclic Loading

    (Received 11 December 2015; accepted 19 May 2016)

    Published Online: 09 September 2016

    CODEN: GTJODJ

      Format Pages Price  
    PDF (6.3M) 18 $25   ADD TO CART

    Cite this document

    X Add email address send
    X
      .RIS For RefWorks, EndNote, ProCite, Reference Manager, Zoteo, and many others.   .DOCX For Microsoft Word



    Abstract

    Experimental observations of the seepage induced response of soils under static and cyclic loading are reported. Hydraulic tests were performed using a modified filtration apparatus designed to capture the response of soils subjected to an upward flow. This apparatus could conveniently monitor various factors influencing the onset of seepage induced failures such as spatio-temporal variations in porosity, average and local hydraulic gradients, and the mean effective stress distribution with depth. Under static conditions, heave and heave-piping failures occurred in densely compacted uniform fine-gravels and fine-sands, respectively, and excessive washout (i.e., suffusion) was observed in gap-graded sandy-gravel soil. Despite this gap-graded soil failing in a similar way under static loading, relatively premature suffusion occurred under cyclic loading that could be attributed to the constant agitation of fines and the development of pore pressure within the pore spaces. The reported results and published data under cyclic loading were compared with various static filtration criteria to assess their potential instability, and they revealed that none could accurately capture their cyclic filtration response. However, at the onset of instability, a unique hydro-mechanical correlation could be observed between the magnitudes of local hydraulic gradients and effective stresses calculated using a proposed stress reduction model. Nevertheless, this correlation governing the inception of instability in reported tests established a clear hydro-mechanical boundary with possible implications for practical filter design under cyclic loading conditions.


    Author Information:

    Israr, J.
    Univ. of Wollongong, Wollongong NSW,

    Indraratna, B.
    Centre for Geomechanics and Railway Engineering, Univ. of Wollongong, Wollongong NSW,

    Rujikiatkamjorn, C.
    Univ. of Wollongong, Wollongong NSW,


    Stock #: GTJ20150288

    ISSN:0149-6115

    DOI: 10.1520/GTJ20150288

    Author
    Title Laboratory Investigation of the Seepage Induced Response of Granular Soils Under Static and Cyclic Loading
    Symposium ,
    Committee D18