Significance and Use
This test method is useful for determining the expansion and bleeding characteristics of freshly mixed fluid hydraulic cement grout commonly used in PA concrete and cementitious post-tensioning tendon grouts.
1. Scope
2. Referenced Documents (purchase separately)
The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C125 Terminology Relating to Concrete and Concrete Aggregates
C937 Specification for Grout Fluidifier for Preplaced-Aggregate Concrete
E1272 Specification for Laboratory Glass Graduated Cylinders
Keywords
bleeding; concrete; expansion; grouts; preplaced-aggregate; preplaced-aggregate concrete; Aggregate; Bleeding; Concrete construction materials/applications; Expansion--concrete materials/applications; Grouts (preplaced-aggregate (PA) concrete); Preplaced-aggregate (PA) concrete; Volumetric measurement--cement/concrete;
ICS Code
ICS Number Code 91.100.30 (Concrete and concrete products)
DOI: 10.1520/C0940-10A
ASTM International is a member of CrossRef.
Citing ASTM Standards
[Back to Top]