    Significance and Use

    This practice provides a standard procedure for selecting proportions for mixtures of grout to be used at fluid consistency in the production of PA concrete meeting applicable criteria for strength, density, and other properties.

    This practice is also useful for determining the composition of grout mixed at fluid consistency and meeting specified requirements for filling voids, cavities, and spaces in rock, foundations, and concrete structures.

    1. Scope

    1.1 This practice describes the laboratory procedure for selecting proportions for grout mixtures required in the production of preplaced-aggregate (PA) concrete.

    1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information purposes only.

    1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    C125 Terminology Relating to Concrete and Concrete Aggregates

    C150 Specification for Portland Cement

    C185 Test Method for Air Content of Hydraulic Cement Mortar

    C219 Terminology Relating to Hydraulic Cement

    C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete

    C637 Specification for Aggregates for Radiation-Shielding Concrete

    C937 Specification for Grout Fluidifier for Preplaced-Aggregate Concrete

    C939 Test Method for Flow of Grout for Preplaced-Aggregate Concrete (Flow Cone Method)

    C940 Test Method for Expansion and Bleeding of Freshly Mixed Grouts for Preplaced-Aggregate Concrete in the Laboratory

    C941 Test Method for Water Retentivity of Grout Mixtures for Preplaced-Aggregate Concrete in the Laboratory

    C942 Test Method for Compressive Strength of Grouts for Preplaced-Aggregate Concrete in the Laboratory

    C943 Practice for Making Test Cylinders and Prisms for Determining Strength and Density of Preplaced-Aggregate Concrete in the Laboratory