Standards

ASTM C1621 / C1621M - 09b


ASTM C1621 / C1621M - 09b Standard Test Method for Passing Ability of Self-Consolidating Concrete by J-Ring


Active Standard ASTM C1621 / C1621M Developed by Subcommittee: C09.47 |Book of Standards Volume: 04.02

more info 5 pages $ 41.00
more info 5 pages $ 41.00
why redline? 10 pages $ 49.20

Historical (view previous versions of standard) ASTM License Agreement Shipping & Handling

More C09.47 Standards Related Products
Copyright/Permissions Standard References

ASTM C1621 / C1621M

Significance and Use

This test method provides a procedure to determine the passing ability of self-consolidating concrete. This test method is applicable for laboratory use in comparing the passing ability of different concrete mixtures. It is also applicable in the field as a quality control test.

The difference between the slump flow and J-Ring flow is an indication of the passing ability of the concrete. A difference less than 25 mm [1 in.] indicates good passing ability and a difference greater than 50 mm [2 in.] indicates poor passing ability. The orientation of the mold for the J-Ring test and for the slump flow test without the J-Ring shall be the same.

This test method is limited to self-consolidating concrete with nominal maximum size of aggregate of up to 25 mm [1 in.].

1. Scope

1.1 This test method covers determination of the passing ability of self-consolidating concrete by using the J-Ring in combination with a mold.

1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.3 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. )


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

C125 Terminology Relating to Concrete and Concrete Aggregates

C143/C143M Test Method for Slump of Hydraulic-Cement Concrete

C172 Practice for Sampling Freshly Mixed Concrete

C173/C173M Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method

C1611/C1611M Test Method for Slump Flow of Self-Consolidating Concrete



Keywords

halo; j-ring; j-ring flow; passing ability self-consolidating concrete; slump flow; spread; Concrete; J-ring; Self-consolidating concrete;



ICS Code

ICS Number Code 91.100.30 (Concrete and concrete products)



DOI: 10.1520/C1621_C1621M-09B

ASTM International is a member of CrossRef.


Citing ASTM Standards

[Back to Top]

Standards Tracker

Standards Subscriptions


Customers frequently also buy:
C1611C1611M
C1610C1610M

Related Standards:
C1611/C1611M
C1712
C1758/C1758M
C1610/C1610M
C94/C94M
See All