Work Item
ASTM WK86073

Withdrawal of D1708-18 With Replacement D0882

Rationale

Per the 2018 rev scope D1708 has already been superseded by ASTM D638 (for larger specimens) and ASTM D882 (for thin sheets / films). There are technical issues with the measurement of elongation in D1708 as the areas outside the reduced section are included in the "gauge length" section, this can result in a 54% error. Either D638 or D882 will be sufficient for any materials that would be tested to D1708.

Details

Developed by Subcommittee: D20.10

Committee: D20

Staff Manager: Alyson Fick

Work Item Status

Date Initiated: 04-24-2023

Technical Contact: Brian Bushey

Item: 000

Ballot:

Status: