Subcommittee F17.67 on Trenchless Plastic Pipeline Technology


    Showing results 1-20 of 20 matching ACTIVE standards under the jurisdiction of F17.67     F17 Home

    F1216-09 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube

        See also WK41228 proposed revision

        See also WK46623 proposed revision

    F1504-14 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation

    F1606-05(2014) Standard Practice for Rehabilitation of Existing Sewers and Conduits with Deformed Polyethylene (PE) Liner

    F1697-09 Standard Specification for Poly(Vinyl Chloride) (PVC) Profile Strip for Machine Spiral-Wound Liner Pipe Rehabilitation of Existing Sewers and Conduit

    F1698-02(2008) Standard Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner and Cementitious Grout for Rehabilitation of Existing Man-Entry Sewers and Conduits

    F1735-09 Standard Specification for Poly (Vinyl Chloride)(PVC) Profile Strip for PVC Liners for Rehabilitation of Existing Man-Entry Sewers and Conduits

        See also WK17580 proposed revision

    F1741-08 Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits

        See also WK40497 proposed revision

    F1743-08 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)

        See also WK27957 proposed revision

        See also WK41229 proposed revision

    F1867-06(2012) Standard Practice for Installation of Folded/Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation

        See also WK40475 proposed revision

    F1871-11 Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation

        See also WK40476 proposed revision

    F1947-10 Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits

    F1962-11 Standard Guide for Use of Maxi-Horizontal Directional Drilling for Placement of Polyethylene Pipe or Conduit Under Obstacles, Including River Crossings

        See also WK27511 proposed revision

    F2019-11 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Pulled in Place Installation of Glass Reinforced Plastic (GRP) Cured-in-Place Thermosetting Resin Pipe (CIPP)

        See also WK39668 proposed revision

        See also WK41230 proposed revision

    F2561-11 Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner

        See also WK47848 proposed revision

    F2599-11 Standard Practice for The Sectional Repair of Damaged Pipe By Means of An Inverted Cured-In-Place Liner

    F2718-09 Standard Specification for Polyethylene (PE) and Cement Materials for an Encapsulated Cement Mortar Formed in Place Liner System (FIPLS) for the Rehabilitation of Water Pipelines

    F2719-09 Standard Practice for Installation of Polyethylene (PE) and Encapsulated Cement Mortar Formed in Place Lining System (FIPLS) for the Rehabilitation of Water Pipelines

        See also WK25903 proposed revision

    F2831-12 Standard Practice for Internal Non Structural Epoxy Barrier Coating Material Used In Rehabilitation of Metallic Pressurized Piping Systems

    F2984-13 Standard Specification for Segmental Panel System for the Grout-in-Place-Liner (GIPL) Rehabilitation Method of Existing Man-Entry Size Sewers, Culverts, and Conduits

    F2994-13 Standard Practice for Utilization of Mobile, Automated Cured-In-Place Pipe (CIPP) Impregnation Systems

    Showing results 1-11 of 11 matching Proposed New Standards under the jurisdiction of F17.67     F17 Home

    WK37681 New Practice for Standard Practice for the means of installation of hydrophillic ends seals for main and lateral pipe lines.

    WK30297 New Practice for Utilization of Mobile, Automated Cured-in-Place Pipe Manufacturing Systems

    WK24074 New Practice for Installation of Machine Spiral Wound High-Density Polyethylene (HDPE) Liner Pipe for Rehabilitation of Existing Sewers and Conduits

    WK24075 New Specification for High-Density Polyethylene (HDPE) Profile Strip for Machine Spiral Wound Liner Pipe Rehabilitation of Existing Sewers and Conduit

    WK46457 New Practice for Structural Rehabilitation Liner Design for Egg-Shaped Sewers

    WK29237 New Practice for the design calculations of close-fit liners

    WK33088 New Practice for Installation of a Polyvinyl Chloride (PVC) Segmental Planel Liner System in Man-Entry-Size Sewers and Conduits

    WK33089 New Practice for The Design of Close-Fit Liners in a Pressure Application

    WK36573 New Practice for The Standard Practice For The Installation Of A Single-Sized Cured-In-Place Liner For Manholes Having Various Sizes.

    WK36574 New Practice for The Installation Of A PVC Pipe Sewer Service Clean out Through A Non-Invasive Small Bore Vacuum Excavation.

    WK36871 New Guide for Vacuum Impregnation of Cured-In-Place Pipe Liners with Thermosetting Resins