Subcommittee F17.67 on Trenchless Plastic Pipeline Technology


    Showing results 1-22 of 22 matching ACTIVE standards under the jurisdiction of F17.67     F17 Home

    F1216-09 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube

        See also WK46623 proposed revision

    F1504-14 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation

    F1606-05(2014) Standard Practice for Rehabilitation of Existing Sewers and Conduits with Deformed Polyethylene (PE) Liner

    F1697-09(2015) Standard Specification for Poly(Vinyl Chloride) (PVC) Profile Strip for Machine Spiral-Wound Liner Pipe Rehabilitation of Existing Sewers and Conduit

    F1698-02(2015) Standard Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner and Cementitious Grout for Rehabilitation of Existing Man-Entry Sewers and Conduits

    F1735-09(2015) Standard Specification for Poly (Vinyl Chloride) (PVC) Profile Strip for PVC Liners for Rehabilitation of Existing Man-Entry Sewers and Conduits

    F1741-08 Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits

        See also WK40497 proposed revision

    F1743-08 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)

    F1867-06(2012) Standard Practice for Installation of Folded/Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation

        See also WK40475 proposed revision

    F1871-11 Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation

        See also WK40476 proposed revision

        See also WK49847 proposed revision

    F1947-10 Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits

    F1962-11 Standard Guide for Use of Maxi-Horizontal Directional Drilling for Placement of Polyethylene Pipe or Conduit Under Obstacles, Including River Crossings

    F2019-11 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Pulled in Place Installation of Glass Reinforced Plastic (GRP) Cured-in-Place Thermosetting Resin Pipe (CIPP)

        See also WK49908 proposed revision

    F2561-11 Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner

        See also WK47848 proposed revision

    F2599-11 Standard Practice for The Sectional Repair of Damaged Pipe By Means of An Inverted Cured-In-Place Liner

    F2718-09(2015) Standard Specification for Polyethylene (PE) and Cement Materials for an Encapsulated Cement Mortar Formed in Place Liner System (FIPLS) for the Rehabilitation of Water Pipelines

    F2719-09(2015) Standard Practice for Installation of Polyethylene (PE) and Encapsulated Cement Mortar Formed in Place Lining System (FIPLS) for the Rehabilitation of Water Pipelines

    F2831-12 Standard Practice for Internal Non Structural Epoxy Barrier Coating Material Used In Rehabilitation of Metallic Pressurized Piping Systems

    F2984-13 Standard Specification for Segmental Panel System for the Grout-in-Place-Liner (GIPL) Rehabilitation Method of Existing Man-Entry Size Sewers, Culverts, and Conduits

    F2985-14 Standard Practice for Installation of a PVC Segmental Panel Liner System in Man-Entry Size Sewers and Conduits

    F2994-13 Standard Practice for Utilization of Mobile, Automated Cured-In-Place Pipe (CIPP) Impregnation Systems

    F3097-15 Standard Practice for Installation of an Outside Sewer Service Cleanout through a Minimally Invasive Small Bore Vacuum Excavation

    Showing results 1-9 of 9 matching Proposed New Standards under the jurisdiction of F17.67     F17 Home

    WK49827 New Practice for New Standard Practice for the Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using Epoxy/Silicate or Silicate Resins to Form a One Piece Main and Lateral Cured-in-Place Liner

    WK30297 New Practice for Utilization of Mobile, Automated Cured-in-Place Pipe Manufacturing Systems

    WK24074 New Practice for Installation of Machine Spiral Wound High-Density Polyethylene (HDPE) Liner Pipe for Rehabilitation of Existing Sewers and Conduits

    WK24075 New Specification for High-Density Polyethylene (HDPE) Profile Strip for Machine Spiral Wound Liner Pipe Rehabilitation of Existing Sewers and Conduit

    WK46457 New Practice for Structural Rehabilitation Liner Design for Egg-Shaped Sewers

    WK36573 New Practice for The Standard Practice For The Installation Of A Single-Sized Cured-In-Place Liner For Manholes Having Various Sizes.

    WK36574 New Practice for The Installation Of A PVC Pipe Sewer Service Clean out Through A Non-Invasive Small Bore Vacuum Excavation.

    WK36871 New Guide for Vacuum Impregnation of Cured-In-Place Pipe Liners with Thermosetting Resins

    WK49210 New Practice for standard practice for the application of polymeric liners inside pipelines.