proposing the following changes in the current ballot
• Section 2: Remove reference document D1898
• Section 5.9: Add robotic sample cutting capability to the apparatus: Other high efficient robotic sample cutting tools can be used as long as the resulting specimens conform to the dimensions of the test specimen
• Section 6.1: Remove section 6.1 related to D1898
• Section 9.1: Increase the relative humidity tolerance from 5% to 10 % in accordance with D618
• Section 10.0: Include procedure for cleaning the puncture probe: Wipe the puncture probe with non-abrasive cloth to remove specimen debris left on the surface of the probe between tests
• Section 10.4: Measure the average thickness of the specimen using caliper by taking average of three readings near the center of the specimen.
Date Initiated: 03-01-2022
Technical Contact: Mahendra Thunga
Item: 016
Ballot: D20 (22-03)
Status: Will Reballot Item