The specification could be improved with some additional points of clarification: 1.Add a comment to the reporting section to indicate the type of failure, adhesion, cohesive, etc. 2.Make an option for a modification to not soak the cylinder halves to mimic an in-situ application. 3.There is the requirement to rod in two layers in 10.3 and three layers in 7.2 4.Modify 7.2 to include any nonabsorbing material such as metal, glass, or plastic.
Date Initiated: 04-11-2018
Technical Contact: Jessica Silva