SYMPOSIA PAPER Published: 01 January 1958
STP45029S

Progress on Metalfilm Strain Gages

Source

The Metalfilm high-temperature strain gage (Fig. 1) was designed to achieve maximum conformability to irregular surfaces. Lateral stability of the unmounted grid was achieved by employing unique extensions of the grid and by making the width of each element approximately one hundred times its thickness. Thus, the mass was extremely small and the surface-to-mass ratio high. Superior bonding strength was achieved. (These gages have been operated at 100,000 g.) An effort was made to reduce drastically the stress concentrations common to other strain gages. Removing the Metalfilm gage from its temporary backing is simple. Cementing it in place is easy. Suitable grids may be cemented to other backing materials to form premounted gages. The side bars provide mechanical protection for the grid. Lead wire ribbons, approximately ten times the thickness of the gage, connect the strain gage tabs with the lead wires by spot welding. Two basic grid configurations are available: (1) one whose width is twice its length, and (2) one whose width is equal to its length. Six effective lengths are standard: 116, 18, 316, 14, 38 and 12 in.

Author Information

Bean, William, T.
Tatnall Measuring Systems Co., Detroit, Mich.
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Developed by Committee: E28
Pages: 12–17
DOI: 10.1520/STP45029S
ISBN-EB: 978-0-8031-5950-1
ISBN-13: 978-0-8031-6104-7