SYMPOSIA PAPER Published: 01 January 1953
STP41691S

Effect of Sigma on Strength and Ductility of 25 Cr, 20 Ni Steel

Source

Sigma in 25 Cr, 20 Ni austenitic stainless steel causes moderate strengthening at room temperature, severe loss in toughness even at temperature as high as 500 F, and moderate loss of creep-rupture strength at 1300 F.

Author Information

Smith, G., V.
Research Laboratory, U. S. Steel Co., Kearny, N. J.
Dulis, E., J.
Research Laboratory, U. S. Steel Co., Kearny, N. J.
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Developed by Committee: E04
Pages: 225–236
DOI: 10.1520/STP41691S
ISBN-EB: 978-0-8031-5920-4
ISBN-13: 978-0-8031-6074-3