SYMPOSIA PAPER Published: 01 January 1987
STP28181S

Grain Dust Probes—Calibration and Measurement

Source

In situ light attenuation and backscattering probes were designed, fabricated, and calibrated for monitoring the dust levels in grain elevators. The calibration was performed both in a dust cloud chamber using mixed grain dust and in an elevator facility with various types of grain. The true dust concentration was determined with an isokinetic sampling probe.

Author Information

Rajendran, N
IIT Research Institute, Chicago, IL
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Developed by Committee: E27
Pages: 294–309
DOI: 10.1520/STP28181S
ISBN-EB: 978-0-8031-5019-5
ISBN-13: 978-0-8031-0957-5