Review of Problems and Requirements in VVER Reactor-Type Pressure Vessel Dosimetry

Source

The main tasks and problems of VVER reactor pressure vessel (RPV) dosimetry are reviewed taking into account the RPV metal characteristics, the peculiarities of surveillance programs and some features of irradiation embrittlement of VVER-440 and VVER-1000 RPV materials. The problems of dosimetry of VVER-1000 surveillance program are discussed separately. The experimental dosimetry programs, which are carried out in this time, are briefly summarized. It's concluded that there are the serious reasons for improvement of VVER dosimetry.

Author Information

Zaritsky, SM
Nuclear Reactors Institute, Russian Research Center “Kurchatov Institute”, Moscow, Russia
Platonov, PA
Institute of Reactor Technology and Materials, Russian Research Center “Kurchatov Institute”, Moscow, Russia
Nikolaev, YA
Institute of Reactor Technology and Materials, Russian Research Center “Kurchatov Institute”, Moscow, Russia
Ošmera, B
Nuclear Research Institute, Řež, Czech Republic
Valenta, V
Institute of Nuclear Physics, Řež, Czech Republic