Source

A common approach to determining if a quenchant will harden a particular alloy is to examine its cooling curve (time-temperature) and compare it to the TTT (time-temperature-transformation) diagram for the alloy of steel to be quenched. Cooling curves for liquid quenchants are generated by using a standard ∅12.5 × 60 mm Inconel alloy probe [1–5].

Author Information

Kobasko, N., I.
Intensive Technologies Ltd., Kyiv, Ohio, Ukraine
Aronov, M., A.
Intensive Technologies Ltd., Kyiv, Ohio, Ukraine
Powell, J., A.
Intensive Technologies Ltd., Kyiv, Ohio, Ukraine
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Developed by Committee: D02
Pages: 45–61
DOI: 10.1520/MNL12068M