Journal Published Online: 01 January 2005
Volume 50, Issue 1

Determination of Elemental Sulfur in Explosives and Explosive Residues by Gas Chromatography-Mass Spectrometry

CODEN: JFSCAS

Abstract

A new method for the positive identification of elemental sulfur in explosives and explosive residues is developed. Following a carbon disulfide wash of explosives or explosive residues, a sample of the extracted material is injected onto a gas chromatography (GC) column, then analyzed via mass-selective (MS) detection. A positive identification of elemental sulfur is based on both retention time and fragmentation pattern. The GC-MS method is demonstrated to be useful in detecting and positively identifying elemental sulfur from both burned and unburned explosive mixtures. With a detection limit of 2.5 ng (2.5 × 10-9 grams) of elemental sulfur on the column, it is shown to be 400 times more sensitive than the presumptive chemical color test that is currently the method employed for detection of small amounts of sulfur.

Author Information

Bradley, KS
Illinois State Police, Springfield Forensic Science Laboratory, Springfield, IL
Pages: 8
Price: $25.00
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Stock #: JFS2004209
ISSN: 0022-1198
DOI: 10.1520/JFS2004209