Standard Historical Last Updated: Nov 07, 2012 Track Document
ASTM G187-05

Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method

Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method G0187-05 ASTM|G0187-05|en-US Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method Standard new BOS Vol. 03.02 Committee G01
$ 73.00 In stock

Significance and Use

The resistivity of the surrounding soil environment is a factor in the corrosion of underground structures. High resistivity soils are generally not as corrosive as low resistivity soils. The resistivity of the soil is one of many factors that influence the service life of a buried structure. Soil resistivity may affect the material selection and the location of a structure.5

Soil resistivity is of particular importance and interest in the corrosion process because it is basic in the analysis of corrosion problems and the design of corrective measures.

The test method is focused to provide an accurate, expeditious measurement of soil resistivity to assist in the determination of a soils corrosive nature. Test Method G 57 emphasizes an in situ measurement commonly utilized in the design of a buried structures corrosion control (cathodic protection systems ground bed design, and so forth). The two-electrode soil box method often compliments the four-pin, in situ soil resistivity method.

The saturated soil resistivity determined by this test method does not necessarily indicate the minimum soil resistivity

Scope

1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures.

1.2 Procedures allow for this test method to be used n the field or in the laboratory.

1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition.

1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 03.02
Developed by Subcommittee: G01.10
Pages: 4
DOI: 10.1520/G0187-05