Standard Historical Last Updated: Oct 11, 2016 Track Document
ASTM E2068-00(2008)

Standard Test Method for Determination of Operating Force of Sliding Windows and Doors

Standard Test Method for Determination of Operating Force of Sliding Windows and Doors E2068-00R08 ASTM|E2068-00R08|en-US Standard Test Method for Determination of Operating Force of Sliding Windows and Doors Standard new BOS Vol. 04.11 Committee E06
$ 75.00 In stock

Significance and Use

This test method determines the operational forces of sliding windows and doors by simulating force applied by hand directly to movable sash or panels. Breakaway and in-motion operating forces are measures of the ease of operation of fenestration products. Product specifications, building codes, and building specifications establish operating force limits as measures of product performance or limits for handicapped accessibility, or both.

Window and door performance standards for air infiltration and water penetration in some cases require operating force measurements to be made and reported as an indication of the operability of the test specimen.

Operating forces can vary significantly from unit to unit due to factors such as installation parameters, wearing of sliding or rolling parts, lubrication, stiffening or softening of weather-strip, and environmental factors (for example, humidity, temperature, accumulation of dirt, and so forth). Therefore, when applied to new product designs, this test method requires that units be tested in a laboratory under controlled conditions including accurate mounting (plumb, square, and level) following the manufacturer's instructions. Use of this test method in the field does not necessarily indicate the operating forces that are inherent in the particular window design, but rather, provides a measurement of the forces required for operation of the particular unit at the particular time. The user is cautioned that installation defects such as bowed jambs, racked frames, or inadequate anchoring can result in binding or sticking of movable components and increased operating forces.

This test method requires measurement of both breakaway and in-motion operating forces. Generally, breakaway force is higher than in-motion operating force due to the difference between static and dynamic friction coefficients or the presence of weather-stripping and sash pockets, or both. Traditional fenestration product standards have required determination of in-motion operating force in the opening direction only and referred to this simply as operating force.

This test method is intended to determine the forces required to operate a window or sliding door which is properly installed and which is operated by hand application of force to a handle, pull bar, or sash member. Application of force through jerking or impact motion is not measured or evaluated by this test method. Operating forces can be significantly different between the opening and closing directions of movement; therefore, this test method involves measurements in both directions of movement.

This test method provides for two procedures which include a dead weight test method (Test Method A) and a force gage test method (Test Method B) of applying and measuring forces required to operate a sliding window or sliding door. When properly applied, both test methods are deemed to produce equivalent results. The dead weight test method is considered to be less likely to be affected by the operator's skill in applying loads in a steady and properly timed manner. The force gage test method is considered simpler to apply and more applicable to field testing where the installation of pulleys and cabling is often impractical. Both test methods are subject to a similar uncertainty.

Scope

1.1 This test method determines the operating forces for opening and closing horizontal and vertical sliding windows and horizontal sliding door systems. It does not address the forces required for opening pivoting, projecting, or other fenestration systems. This test method does not address the use or performance of add-on devices or mechanical operators that might be installed to reduce operating forces of sliding windows or doors. It deals only with the forces necessary to open and close a sash or panel through the direct application of force to the operable sash or panel.

1.2 This test method is suitable for laboratory product comparisons or for qualifying products, or both, as meeting window or door operating force specifications. This test method is also suitable for use in the field to determine the operating forces required to open and close installed sliding windows and doors.

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are SI units provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 7.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 04.11
Developed by Subcommittee: E06.51
Pages: 8
DOI: 10.1520/E2068-00R08
ICS Code: 91.060.50