Standard Historical Last Updated: Oct 11, 2019 Track Document
ASTM E1518-05(2012)

Standard Practice for Evaluation of Physical Compatibility of Pesticides in Aqueous Tank Mixtures by the Dynamic Shaker Method

Standard Practice for Evaluation of Physical Compatibility of Pesticides in Aqueous Tank Mixtures by the Dynamic Shaker Method E1518-05R12 ASTM|E1518-05R12|en-US Standard Practice for Evaluation of Physical Compatibility of Pesticides in Aqueous Tank Mixtures by the Dynamic Shaker Method Standard new BOS Vol. 11.08 Committee E35
$ 66.00 In stock

Significance and Use

This practice is designed for researchers, applicators, and end users of pesticides where one or more ingredients are being mixed into an aqueous spray system. The practice is useful in determining physical compatibility of aqueous spray mixtures of pesticides and/or fertilizers.

The practice is not designed to determine physical compatibility of non-aqueous based spray mixtures.

4.3 THe results or the testing should be used to determine the compatibility of the mixture ingredients in dynamic applications. Interpolation of static results to the expectations of the results of this test is not encouraged.

Scope

1.1 This practice describes the method for the evaluation of the physical compatibility and stability of pesticide tank mixtures diluted for aqueous application. This practice may also be adapted to use with liquid fertilizers in replacement of the water diluent.

1.2 Tank mix compatibility can be affected by many variables. Care should be taken to duplicate test conditions. This practice addresses the standard variables such as time, temperature, water hardness, method of agitation, and degree of agitation.

1.3 Compatibility is complex and can be affected by other variables such as order of addition, pH of the dilution water, pumping shear, etc. Under the parameters of this practice, the results will define whether the pesticide mixture is or is not compatible in the laboratory. Compatibility or incompatibility should be confirmed under field spray conditions.

1.4 Proper safety and hygiene precautions must be taken when working with pesticide formulations to prevent skin or eye contact, vapor inhalation, and environmental contamination.

1.5 Read and follow all handling instructions for the specific formulation and conduct the test in accordance with good laboratory practice.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 11.08
Developed by Subcommittee: E35.22
Pages: 3
DOI: 10.1520/E1518-05R12
ICS Code: 65.100.01