Standard Historical Last Updated: Aug 16, 2017 Track Document
ASTM E309-95(2001)

Standard Practice for Eddy-Current Examination of Steel Tubular Products Using Magnetic Saturation

Standard Practice for Eddy-Current Examination of Steel Tubular Products Using Magnetic Saturation E0309-95R01 ASTM|E0309-95R01|en-US Standard Practice for Eddy-Current Examination of Steel Tubular Products Using Magnetic Saturation Standard new BOS Vol. 03.03 Committee E07
$ 83.00 In stock

Scope

1.1 This practice covers a procedure for applying the eddy-current method to detect discontinuities in ferromagnetic pipe and tubing (Note 1) where the article being examined is rendered substantially non-magnetic by the application of a concentrated, strong magnetic field in the region adjacent to the examining coil.

Note 1—For convenience, the term tube or tubular product will hereafter be used to refer to both pipe and tubing.

1.2 The procedure is specifically applicable to eddy-current examination methods using an encircling-coil assembly. However, eddy-current techniques that employ either fixed or rotating probe-coil assemblies may be used to either enhance discontinuity sensitivity on the large diameter tubular products or to maximize the response received from a particular type of discontinuity.

1.3 This practice is intended for use on tubular products having outside diameters from approximately 1/4 to 10 in. (6.35 to 254.0 mm). These techniques have been used for smaller and larger sizes however, and may be specified upon contractural agreement between the purchaser and the supplier.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 03.03
Developed by Subcommittee: E07.07
Pages: 5
DOI: 10.1520/E0309-95R01
ICS Code: 23.040.10; 77.140.75