Standard Historical Last Updated: Dec 31, 2010 Track Document
ASTM D6089-97(2003)

Standard Guide for Documenting a Ground-Water Sampling Event

Standard Guide for Documenting a Ground-Water Sampling Event D6089-97R03 ASTM|D6089-97R03|en-US Standard Guide for Documenting a Ground-Water Sampling Event Standard new BOS Vol. 04.09 Committee D18
$ 66.00 In stock

Significance and Use

When sampling ground-water monitoring wells, it is very important to thoroughly document all field activities. Sufficient field data should be retained to allow one to reconstruct the procedures and conditions that may have affected the integrity of a sample. The field data generated are vital to the interpretation of the chemical data obtained from laboratory analyses of samples. Field data and observations may also be useful to analytical laboratory personnel.

Abstract

This guide covers what and how information should be recorded in the field when sampling a ground-water monitoring well. This guide is limited to written documentation of a ground-water sampling event. When sampling ground-water monitoring wells, it is very important to thoroughly document all field activities. It is important to record procedures used and measurements immediately after they have been accomplished and are fresh in the memory. The format of the documentation is discretionary, but should be consistent from well to well and in accordance with regulatory requirements.

Scope

1.1 This guide covers what and how information should be recorded in the field when sampling a ground-water monitoring well. Following these recommendations will provide adequate documentation in most monitoring programs. In some situations, it may be necessary to record additional or different information, or both, to thoroughly document the sampling event. In other cases, it may not be necessary to record all of the information recommended in this guide. The level of documentation will be based on site-specific conditions and regulatory requirements.

1.2 This guide is limited to written documentation of a ground-water sampling event. Other methods of documentation (that is, electronic and audiovisual) can be used but are not addressed in this guide. The specific activities addressed in this guide include documentation of static water level measurement, monitoring well purging, monitoring well sampling, field measurements, ground-water sample preparation, and ground-water sample shipment.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.4 This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project's many unique aspects. The word "Standard" in the title of this document means only that the document has been approved through the ASTM consensus process.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 04.09
Developed by Subcommittee: D18.21
Pages: 3
DOI: 10.1520/D6089-97R03
ICS Code: 13.060.10