Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer D5481-04 ASTM|D5481-04|en-US Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer Standard new BOS Vol. 05.02 Committee D02
$ 83.00 In stock

Significance and Use

Viscosity is an important property of fluid lubricants. The viscosity of all fluids varies with temperature. Many common petroleum lubricants are non-Newtonian: their viscosity also varies with shear rate. The usefulness of the viscosity of lubricants is greatest when the viscosity is measured at or near the conditions of shear rate and temperature that the lubricants will experience in service.

The conditions of shear rate and temperature of this test method are thought to be representative of those in the bearing of automotive engines in severe service.

Many equipment manufacturers and lubricant specifications require a minimum high-temperature high-shear viscosity at 150°C and 106 s1. The shear rate in capillary viscometers varies across the radius of the capillary. The apparent shear rate at the wall for this test method is increased to compensate for the variable shear rate.3

This test was evaluated in an ASTM cooperative program.6

Scope

1.1 This test method covers the laboratory determination of high-temperature high-shear (HTHS) viscosity of engine oils at a temperature of 150°C using a multicell capillary viscometer containing pressure, temperature, and timing instrumentation. The shear rate for this test method corresponds to an apparent shear rate at the wall of 1.4 million reciprocal seconds (1.4 x 106 s-1). This shear rate has been found to decrease the discrepancy between this test method and other high-temperature high-shear test methods3 used for engine oil specifications. Viscosities are determined directly from calibrations that have been established with Newtonian oils with viscosities from 2 to 5 mPa·s at 150°C.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 05.02
Developed by Subcommittee: D02.07
Pages: 5
DOI: 10.1520/D5481-04
ICS Code: 75.100