Standard Historical Last Updated: Aug 16, 2017 Track Document
ASTM D4453-02

Standard Practice for Handling of Ultra-Pure Water Samples

Standard Practice for Handling of Ultra-Pure Water Samples D4453-02 ASTM|D4453-02|en-US Standard Practice for Handling of Ultra-Pure Water Samples Standard new BOS Vol. 11.01 Committee D19
$ 73.00 In stock

Scope

1.1 This practice covers concepts for handling ultra-pure water samples needed for the measurement of ever-decreasing levels of specified impurities that are encountered in the operation of modern high-pressure boilers and turbines. The handling of blanks associated with the analysis of ultra-pure water samples is also covered by this practice. The techniques presented can help the investigator increase the accuracy of analyses performed.

1.2 This practice is applicable to water and steam samples from "zero solids treated" once-through or drum-type boilers, reactor coolant water, electronic grade water, or any other process water where analyte concentrations are in the low parts per billion (micrograms per litre) range.

1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in 5.2.3.5, 5.1, and 5.3.7.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 11.01
Developed by Subcommittee: D19.03
Pages: 3
DOI: 10.1520/D4453-02
ICS Code: 13.060.30