Standard Historical Last Updated: Jun 10, 2011 Track Document
ASTM D3278-96(2004)e1

Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus

Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus D3278-96R04E01 ASTM|D3278-96R04E01|en-US Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus Standard new BOS Vol. 06.01 Committee D01
$ 75.00 In stock

Significance and Use

Flash point is one of the properties used to define the flammability of a liquid. It is used to classify liquids according to their flammability by governmental regulatory agencies. It may also be used to determine the presence of impurities or contaminants in a given liquid, such as the presence of residual solvents in solvent-refined drying oils. See Test Methods D 56 and D 93 for alternate flash point testing.

Scope

1.1 These test methods cover procedures for determining whether a material does or does not flash at a specified temperature or for determining the lowest finite temperature at which a material does flash when using a small scale closed-cup apparatus. The test methods are applicable to paints, enamels, lacquers, varnishes, and related products having a flash point between 0 and 110C (32 and 230F) and viscosity lower than 150 St at 25C (77F). Note 1Tests at higher or lower temperatures are possible.

Note 2

More viscous materials may be tested in accordance with .

Note 3

Organic peroxides may be tested in accordance with , which describes the applicable safety precautions.

Note 4

The U.S. Department of Labor (OSHA, Hazard Communications), the U.S. Department of Transportation (RSPA), and the U.S. Environmental Protection Agency (EPA) have specified Test Methods D 3278 as one of several acceptable methods for the determination of flash point of liquids in their regulations.

Note 5

These test methods are similar to International Standards ISO 3679 and ISO 3680.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 This standard should be used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions and should not be used to describe or appraise the fire-hazard or fire-risk of materials, products, or assemblies under actual fire conditions. However, results of the test may be used as elements of a fire-hazard or a fire-risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard or fire risk of a particular end use

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see and .

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 06.01
Developed by Subcommittee: D01.21
Pages: 8
DOI: 10.1520/D3278-96R04E01
ICS Code: 13.220.40; 87.040