Standard Historical Last Updated: Jul 08, 2013 Track Document
ASTM D746-07

Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact

Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact D0746-07 ASTM|D0746-07|en-US Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact Standard new BOS Vol. 08.01 Committee D20
$ 75.00 In stock

Significance and Use

This test method establishes the temperature at which 50 % of the specimens tested fail when subjected to the conditions specified herein. The test provides for the evaluation of long-time effects such as crystallization, or those effects that are introduced by low-temperature incompatibility of plasticizers in the material under test. Plastics and elastomers are used in many applications requiring low-temperature flexing with or without impact. Use data obtained by this method to predict the behavior of plastic and elastomeric materials at low temperatures only in applications in which the conditions of deformation are similar to those specified in this test method. This test method has been found useful for specification purposes, but does not necessarily measure the lowest temperature at which the material is suitable for use.

FIG. 1 Dimensional Requirements Between Specimen Clamp and Striking Edge (Type A)

FIG. 2 Typical Clamp (Type A)

Note—Dimensions are in millimetres.

FIG. 3 Dimensional Details of Striking Edge and Clamping Device, Type B (Positioning of Unnotched Test Specimen)

FIG. 4 Assembled Clamp with Test Specimens, Type B

Scope

1.1 This test method covers the determination of the temperature at which plastics and elastomers exhibit brittle failure under specified impact conditions. Two routine inspection and acceptance procedures are also provided.

Note 1—When testing rubbers for impact brittleness use Test Methods D 2137.

1.2 The values stated in SI units are to be regarded as the standard.

1.3 Due to the potential safety and environmental hazards associated with mercury-filled thermometers, the use of alternative temperature measuring devices (such as thermocouples and RTDs) is encouraged.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 2—This test method and ISO 974 (E) are technically equivalent when using the Type B fixture and the Type III specimen, however, the minimum number of specimens that are required to be tested is significantly different when using this test method. The ISO method requires that a minimum of 100 specimens be tested.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 08.01
Developed by Subcommittee: D20.30
Pages: 8
DOI: 10.1520/D0746-07
ICS Code: 83.060; 83.080.01