Scope

1.1 This specification applies to faced or unfaced, rigid cellular phenolic thermal insulation in either board or tubular form. It does not apply to field expanded cellular phenolic materials.

1.2 Materials covered by this specification are used as roof insulation; sheathing or rigid board for non-load bearing, building material applications; and pipe insulation for use between -40 and 257oF (-40 and 125oC). Type II Grade 1 and Type III Grade 1 materials with an appropriate vapor retarder covering on the warm surface can be used to a lower temperature limit of -290oF (-180oC). (See 7.2.)

1.3 The values stated in inch-pound units are to be regarded as standard. International Standard Units (SI) are given in parentheses.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 16 .

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 04.06
Developed by Subcommittee: C16.22
Pages: 5
DOI: 10.1520/C1126-00
ICS Code: 83.100