Standard Historical Last Updated: Nov 14, 2019 Track Document
ASTM C840-19a

Standard Specification for Application and Finishing of Gypsum Board

Standard Specification for Application and Finishing of Gypsum Board C0840-19A ASTM|C0840-19A|en-US Standard Specification for Application and Finishing of Gypsum Board Standard new BOS Vol. 04.01 Committee C11
$ 119.00 In stock

Abstract

This specification covers requirements for the methods of application and finishing of gypsum board. Construction details for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories. Gypsum board assembly shall conform to acoustical tests of the specification where sound control is required. Moreover, gypsum assembly shall conform to framing size, fasteners spacing, ventilation, substrate, surface preparation, cutting, and installation application as indicated in the specification. Materials categorized under this specification include: gypsum boards, gypsum wallboards, gypsum backing board and coreboard, water-resistant gypsum backing board, exterior gypsum soffit board, and gypsum ceiling board. Finishing materials include: compounds, joint tape, fasteners, nails, screws, and staples. A fire test of assemblies shall be conducted to determine a fire resistance rating required for gypsum board assembly. Gypsum board shall be cut by scoring and breaking or by sawing, working from the face side. Masonry or concrete walls shall be dry, free of dust, oil, or form release agents, protrusions or voids, or foreign matter that inhibit bond for adhesively applied gypsum board. All materials shall be kept dry. Where gypsum board is stored outside, it shall be off the ground, properly supported on a level platform and fully protected from the weather or direct sunlight exposure.

Scope

1.1 This specification covers the minimum requirements for the methods of application and finishing of gypsum board, including related items and accessories.

1.2 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories.

1.2.1 Where this specification is more stringent (size or thickness of framing: size and spacing of fasteners) than the fire-rated construction, this specification shall govern.

1.3 Where sound control is required for a gypsum board assembly, details of construction shall be in accordance with reports of acoustical tests of assemblies that have met the required acoustical values.

1.4 Unheated spaces above gypsum board ceilings shall be properly ventilated (see Appendix X2).

1.5 The various application systems are located in the following sections:

I

Application of Single-ply Gypsum Board to Wood Framing Members

8

II

Application of Two-ply Gypsum Board to Wood Framing Members

9

III

Application of Gypsum Board by Adhesive Nail-on to Wood Framing
     Members

10

IV

Semi-solid Gypsum Board Partitions

11

V

Solid Gypsum Board Partitions

12

VI

Application of Gypsum Board with Adhesives to Interior Masonry or
     Concrete Walls

13

VII

Application of Gypsum Board to Rigid Foam Insulation

14

VIII

Application of Gypsum Board to Steel Framing and Furring

15

IX

Arches and Bending Radii

16

X

Application of Gypsum Board to Receive Tile by Adhesive Application

17

XI

Exterior Application of Gypsum Wallboard and Exterior Gypsum Soffit
     Board

18

XII

Floating Interior Angles

19

XIII

Control (Expansion) Joints

20

XIV

Foil-backed Gypsum Board

21

XV

Application of Vinyl Faced Gypsum Board

22

1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.7 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.

1.8 The following precautionary caveat pertains only to Sections 6 – 26. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

For specific precautionary statements, see 4.1.1, 4.1.2, and 24.5.

1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 04.01
Developed by Subcommittee: C11.03
Pages: 22
DOI: 10.1520/C0840-19A
ICS Code: 91.100.10