Standard Historical Last Updated: Jul 28, 2011 Track Document
ASTM C25-06

Standard Test Methods for Chemical Analysis of Limestone, Quicklime, and Hydrated Lime

Standard Test Methods for Chemical Analysis of Limestone, Quicklime, and Hydrated Lime C0025-06 ASTM|C0025-06|en-US Standard Test Methods for Chemical Analysis of Limestone, Quicklime, and Hydrated Lime Standard new BOS Vol. 04.01 Committee C07
$ 119.00 In stock

Significance and Use

These test methods provide accurate and reliable analytical procedures to determine the chemical constituents of limestone, quicklime, and hydrated lime (See Note 1). The percentages of specific constituents which determine a material’quality or fitness for use are of significance depending upon the purpose or end use of the material. Results obtained may be used in relation to specification requirements.

Because quicklime and hydrated lime quickly absorb water and carbon dioxide from the air, precision and bias are extremely dependent upon precautions taken during sample preparation and analysis to minimize excessive exposure to ambient conditions.

Note 1—These test methods can be applied to other calcareous materials if provisions are made to compensate for known interferences.

Scope

1.1 These test methods cover the chemical analysis of high-calcium and dolomitic limestone, quicklime, and hydrated lime. These test methods are classified as either standard (preferred) or alternative (optional).

1.2 The standard test methods are those that employ classical gravimetric or volumetric analytical procedures and are typically those required for referee analyses where chemical specification requirements are an essential part of contractual agreement between buyer and seller.

1.3 Alternative or optional test methods are provided for those who wish to use procedures shorter or more convenient than the standard methods for the routine determinations of certain constituents. Optional test methods may sometimes be preferred to the standard test methods, but frequently the use of modern and expensive instrumentation is indicated which may not be accessible to everyone. Therefore, the use of these test methods must be left to the discretion of each laboratory.

1.4 The analytical procedures appear in the following order:

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see , , , , , and .

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 04.01
Developed by Subcommittee: C07.05
Pages: 36
DOI: 10.1520/C0025-06
ICS Code: 91.100.10