    ASTM F1947-10

    Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits (Withdrawn 2019)

    Withdrawn Standard: ASTM F1947-10 | Developed by Subcommittee: F17.67


      Format Pages Price  
    PDF 5 $58.00   ADD TO CART


    Withdrawn Rationale:

    This practice describes the procedures for the rehabilitation of sewer lines and conduits (4 to 15 in. diameter) by the insertion of a folded PVC pipe, which is heated, pressurized, and expanded against the interior surface of an existing pipe with either a mechanical rounding device or steam pressure. The finished PVC pipe will be continuous and conform to the existing conduit. This rehabilitation process can be used in a variety of non–pressure applications, such as: sanitary sewers, storm sewers, and process piping.

    Formerly under the jurisdiction of Committee F17 on Plastic Piping Systems, this practice was withdrawn in February 2019 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

    1. Scope

    1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits (4 to 15 in. diameter) by the insertion of a folded PVC pipe, which is heated, pressurized, and expanded against the interior surface of an existing pipe with either a mechanical rounding device or steam pressure. The finished PVC pipe will be continuous and conform to the existing conduit. This rehabilitation process can be used in a variety of nonpressure applications, such as: sanitary sewers, storm sewers, and process piping.

    1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

    1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.



    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials

    D1600 Terminology for Abbreviated Terms Relating to Plastics

    D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds

    D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings

    F412 Terminology Relating to Plastic Piping Systems

    F1417 Practice for Installation Acceptance of Plastic Non-pressure Sewer Lines Using Low-Pressure Air

    F1504 Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation

    NASSCO Standard

    Recommended Specifications for Sewer Collection System Rehabilitation 11521 Cronridge Drive, Suite J Owings Mills, MD 21117. www.nassco.org.


    Referencing This Standard
    Link Here
    Link to Active (This link will always route to the current Active version of the standard.)

    DOI: 10.1520/F1947-10

    Citation Format

    ASTM F1947-10, Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits (Withdrawn 2019), ASTM International, West Conshohocken, PA, 2010, www.astm.org

    Back to Top