    ASTM F1266-89(2008)

    Standard Performance Specification for Cerebral Stereotactic Instruments (Withdrawn 2017)

    Withdrawn Standard: ASTM F1266-89(2008) | Developed by Subcommittee: F04.31


      Format Pages Price  
    PDF 6 $55.20   ADD TO CART


    Withdrawn Rationale:

    This specification covered stereotactic instruments used by neurosurgeons to assist in the placement of probes, such as cannulae, needles, forceps, or electrodes or to direct radiation into brain regions or anatomical targets that are not visible on the surface.

    Formerly under the jurisdiction of Committee F04 on Medical and Surgical Materials and Devices, this specification was withdrawn in July 2017 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

    1. Scope

    1.1 This specification covers stereotactic instruments used by neurosurgeons to assist in the placement of probes, such as cannulae, needles, forceps, or electrodes or to direct radiation into brain regions or anatomical targets that are not visible on the surface. The general location of these regions is determined by measurements from landmarks visualized by X ray or other means, such measurements being based on atlases derived from anatomical studies and autopsy. Because of the anatomical variability, more precise location in any single patient may be determined by physiological responses in that patient. The degree of success in stereotactic surgery depends upon the experience of the surgeon as well as the precision of the stereotactic instrument. Nevertheless, minimum standards of accuracy for stereotactic instruments that are within the range of variability of human anatomy must be maintained.

    1.2 For the purpose of this specification, a stereotactic instrument is a guiding device used in human neurosurgery for the purpose of directing an instrument or treating modality to a specific point within the brain by radiographic or other visualization of landmarks.

    1.3 Stereotactic instruments must be constructed to afford the surgeon reliably reproducible accuracy in placing instruments into target areas. Proper positioning of the probe is often verified by X rays to control errors in calculation and to correct deflection of the probe during insertion. Physiological parameters may be used to further define the optimal target.

    1.4 At the present time, stereotactic instruments are used most frequently, but not exclusively in the following operations. The list is presented only to present examples and should not be construed to restrict advances or developments of new procedures. For some applications it is not required to hit a point in space, but to hit a volume or make a lesion within a mass. For that purpose, devices other than those covered by this specification may be employed, but should be restricted to such uses:

    1.4.1 Thalamotomy for parkinsonism and other types of tremor,

    1.4.2 Electrode implantation for epilepsy,

    1.4.3 Needle or magnetic insertion, or both, for aneurysm thrombosis,

    1.4.4 Thalamic or subthalamic operations for dystonia,

    1.4.5 Thalamic or subthalamic operations for involuntary movements such as chorea or hemiballismus,

    1.4.6 Ablation of deep cerebellar nuclei for spasticity,

    1.4.7 Cingulotomy and thalamic or subthalamic surgery for pain,

    1.4.8 Mesencephalotomy or tractotomy for pain,

    1.4.9 Ablations of subcortical temporal lobe structures for treatment of epilepsy,

    1.4.10 Psychosurgical procedures,

    1.4.11 Implantation of depth stimulating electrodes for pain,

    1.4.12 Insertion of forceps or needle for obtaining biopsy specimens,

    1.4.13 Foreign body removal,

    1.4.14 Implantation of radioactive material, and

    1.4.15 Biopsy or treatment of tumors.

    1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.



    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    NFPA Standard

    NFPA 99 Health Care Facilities Code (56A and 76B-T) Available from National Fire Protection Association (NFPA), 1 Batterymarch Park, Quincy, MA 02169-7471, http://www.nfpa.org.

    UL Standard

    UL 544 Electrical, Medical, and Dental Equipment Available from Underwriters Laboratories (UL), 333 Pfingsten Rd., Northbrook, IL 60062-2096, http://www.ul.com.


    Referencing This Standard
    Link Here
    Link to Active (This link will always route to the current Active version of the standard.)

    DOI: 10.1520/F1266-89R08

    Citation Format

    ASTM F1266-89(2008), Standard Performance Specification for Cerebral Stereotactic Instruments (Withdrawn 2017), ASTM International, West Conshohocken, PA, 2008, www.astm.org