Standard Active Last Updated: Aug 11, 2023 Track Document
ASTM E3231-19

Standard Guide for Cell Culture Growth Assessment of Single-Use Material

Standard Guide for Cell Culture Growth Assessment of Single-Use Material E3231-19 ASTM|E3231-19|en-US Standard Guide for Cell Culture Growth Assessment of Single-Use Material Standard new BOS Vol. 14.01 Committee E55
$ 63.00 In stock
ASTM International

Significance and Use

5.1 A risk-based approach must be used to determine the cell lines, test articles, and materials used for testing. An evaluation of relevant factors should be made to determine if a test article is representative of the intended use.

5.2 Cell culture compatibility should be assessed if the material is in direct contact with cell culture medium regardless of duration of contact. Test articles can be of a single material or assembled from a multitude of materials.

5.3 Two perspectives to single-use material cell culture compatibility assessments are the supplier and the end user perspectives. It is understood that the supplier may have better access to single-use materials and material manufacturing processes, while having limited access to representative cell lines. Supplier assessment of materials are best tested using cell lines available that have shown known material sensitivity. The end users may have more limited access to materials but access to more representative cell lines and processes. Therefore assessment of compatibility of material with a specific cell line in a process is best evaluated by the end user.

5.4 This guide outlines best practices to establish test procedures. Appendix X1 outlines an example test procedure for a commercially available CHO cell line.

Scope

1.1 This guide outlines best practices to consider when setting up a representative leachable test method to detect if a material is compatible with cell culture media or manufacturing processes. This guide does not replace or supersede cell growth tests like USP <87>, USP <88> (plastic/elastomeric materials), or ISO 10993 (medical device materials), that are used in assessing biological reactivity in humans. Polymeric materials that have passed these tests have been found to leach compounds under normal process conditions that can inhibit cell culture growth for some cell lines. See Refs (1-5).2 Test methods that are representative of the manufacturing conditions will help identify materials that are appropriate for use during manufacturing.

1.2 This guide may be relevant to biopharmaceutical manufacturing, cell-based therapeutics, vaccines, cell-based diagnostics, and other areas.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Price: