Standard Historical Last Updated: May 09, 2011 Track Document
ASTM D5602-98(2006)

Standard Test Method for Static Puncture Resistance of Roofing Membrane Specimens

Standard Test Method for Static Puncture Resistance of Roofing Membrane Specimens D5602-98R06 ASTM|D5602-98R06|en-US Standard Test Method for Static Puncture Resistance of Roofing Membrane Specimens Standard new BOS Vol. 04.04 Committee D08
$ 66.00 In stock

Significance and Use

An important factor affecting the performance of many membrane roofing systems is their ability to resist static puncture loads. This test method provides a means for assessing static puncture resistance.

This test method can be used to compare the puncture resistance of a single type of membrane as a function of a variety of insulation substrates or, conversely, to compare the resistance of a number of membrane specimens set on a single type of insulation.

The effect of temperature on puncture resistance can be studied by conducting the test under controlled conditions using such equipment as an environmental chamber, oven, or freezer.

This test method can be useful for developing performance criteria for membrane roofing systems.

This test method can be useful for developing classifications of the static puncture resistance of membrane roofing systems.

While it is considered that the results obtained by this laboratory test can afford a measure of the static puncture resistance of membrane roofing systems in the field provided that service loads and temperature conditions are known, no direct correlation has yet been established.

Scope

1.1 This test method covers evaluation of the maximum static puncture load that roofing membrane samples can withstand without allowing the passage of water.

1.2 This laboratory test is conducted at any desired temperature using sheet membrane samples manufactured in a factory or prepared in a laboratory.

1.3 Roof membrane specimens to which the test method is applicable include bituminous built up, polymer-modified bitumens, vulcanized rubbers, non-vulcanized polymeric, and thermoplastic materials.

1.4 This test method is not applicable to aggregate-surfaced membrane specimens, but it is applicable to specimens having factory-applied granules.

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.