Standard Active Last Updated: Aug 02, 2023 Track Document
ASTM C1787-23

Standard Specification for Installation of Non Metallic Plaster Bases (Lath) Used with Portland Cement Based Plaster in Vertical Wall Applications

Standard Specification for Installation of Non Metallic Plaster Bases (Lath) Used with Portland Cement Based Plaster in Vertical Wall Applications C1787-23 ASTM|C1787-23|en-US Standard Specification for Installation of Non Metallic Plaster Bases (Lath) Used with Portland Cement Based Plaster in Vertical Wall Applications Standard new BOS Vol. 04.01 Committee C11
$ 55.00 In stock
ASTM International

Abstract

This specification describes the minimum requirements for the installation of non-metallic plaster bases used with portland cement-based plaster in vertical wall applications. In cases where a fire resistance rating is required for plastered assemblies and constructions, the construction details shall conform to reports of fire tests of assemblies that have satisfied the requirements of the fire rating imposed. The standard defines the requirements with respect to delivery and storage of materials, coordination and scheduling of installation, application of accessories, and application of non-metallic plaster bases.

Scope

1.1 This specification applies to the minimum installation requirements for non metallic plaster bases used with portland cement based plaster in vertical wall applications.

1.2 Where a fire resistance rating is required for plastered assemblies and constructions, details of construction shall be in accordance with reports of fire tests of assemblies that have met the requirements of the fire rating imposed.

1.3 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.

1.4 Details of construction for a specific assembly to achieve the required fire resistance, sound or acoustic rating shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing, sound or acoustic laboratories.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 04.01
Developed by Subcommittee: C11.03
Pages: 3
DOI: 10.1520/C1787-23
ICS Code: 91.100.10