    ASTM C1478M-19

    Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals (Metric) (Withdrawn 2020)

    Withdrawn Standard: ASTM C1478M-19 | Developed by Subcommittee: C13.06


      Format Pages Price  
    PDF 3 $54.00   ADD TO CART


    Withdrawn Rationale:

    This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.

    Formerly under the jurisdiction of Committee C13 on Concrete Pipe, this specification was withdrawn in September 2020 and combined with Specification C1478 to become C1478/C1478M.1

    1. Scope

    1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connections between precast reinforced concrete storm sewer structures conforming to Specification C478 and pipes, and between precast reinforced concrete pipe and laterals for storm drainage systems.

    1.1.1 These connectors are designed to prevent soil migration between the pipe and storm sewer structure, and between the pipe and lateral.

    1.2 This specification is the SI companion to C1478.

    Note 1: This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specification are adequate for hydrostatic pressures up to 41 kPa (4.3 m) without leakage when tested in accordance with Section 7. Infiltration quantities for an installed system are dependent upon many factors other than the connections between storm sewer structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.

    Note 2: For installations that exceed 41 kPa (4.3 m), the user is cautioned to verify the amount of hydrostatic head pressure the connector will experience. If the total pressure applied to the connector exceeds the 41 kPa limits of the specification, the user is advised to contact the connector manufacturer for alternative methods of connecting the pipe, or applicable alternative standards.

    1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific warning statement, see 7.2.4.

    1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.



    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    A493 Specification for Stainless Steel Wire and Wire Rods for Cold Heading and Cold Forging

    A666 Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar

    C478 Specification for Circular Precast Reinforced Concrete Manhole Sections

    C822 Terminology Relating to Concrete Pipe and Related Products

    C913 Specification for Precast Concrete Water and Wastewater Structures

    D395 Test Methods for Rubber PropertyCompression Set

    D412 Test Methods for Vulcanized Rubber and Thermoplastic ElastomersTension

    D471 Test Method for Rubber PropertyEffect of Liquids

    D543 Practices for Evaluating the Resistance of Plastics to Chemical Reagents

    D573 Test Method for RubberDeterioration in an Air Oven

    D624 Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers

    D883 Terminology Relating to Plastics

    D1149 Test Methods for Rubber DeteriorationCracking in an Ozone Controlled Environment

    D1566 Terminology Relating to Rubber

    D2137 Test Methods for Rubber PropertyBrittleness Point of Flexible Polymers and Coated Fabrics

    D2240 Test Method for Rubber PropertyDurometer Hardness


    Referencing This Standard
    Link Here
    Link to Active (This link will always route to the current Active version of the standard.)

    DOI: 10.1520/C1478M-19

    Citation Format

    ASTM C1478M-19, Standard Specification for Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes, and Laterals (Metric) (Withdrawn 2020), ASTM International, West Conshohocken, PA, 2019, www.astm.org

    Back to Top