SYMPOSIA PAPER Published: 01 January 1958
STP45047S

Investigation of Strain Gages for Long-Time Static Testing to 650 F

Source

Results are presented of a series of tests on the performance of HT 600 wire strain gages, at elevated temperatures over long periods of time. These gages showed no zero shift at temperatures below 650 F in over 300 hr of testing. The gage-to-gage consistency in the apparent strain versus temperature curves was within ±150 microinches per in. to 600 F.

Author Information

Yanowitz, Herbert
Foster Wheeler Corp., New York, N. Y.
Berman, Irwin
Foster Wheeler Corp., New York, N. Y.
Bleiweis, Alfred
Foster Wheeler Corp., New York, N. Y.
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Developed by Committee: E28
Pages: 142–150
DOI: 10.1520/STP45047S
ISBN-EB: 978-0-8031-5950-1
ISBN-13: 978-0-8031-6104-7