    STP1591

    Orthopaedic Surgeon Modularity Utilization and Surgical Technique Considerations in the Face of Implant Corrosion

    Published: 2016


      Format Pages Price  
    PDF (108K) 7 $25   ADD TO CART
    Complete Source PDF (57M) 463 $126   ADD TO CART

    Cite this document

    X Add email address send
    X
      .RIS For RefWorks, EndNote, ProCite, Reference Manager, Zoteo, and many others.   .DOCX For Microsoft Word


    Abstract

    The use of modular femoral components for total hip arthroplasty (THA) allows surgeons to adjust leg lengths, restore anatomy, and improve stability through alterations in femoral offset, neck length, and version; however, corrosion, fretting, and fatigue failure have raised concerns about these implants. To determine surgeons' opinions and trends regarding the use of modularity in THA, during 2013 and 2014 surveys were sent to American Academy of Orthopaedic Surgeons fellows to investigate the use of modularity in THA. The survey included questions regarding technique and basic science knowledge of modular components. Results from 2013 and 2014 were compared to evaluate trends in modular component use. Ninety-nine surgeons (2013) and 106 surgeons (2014) responded, more than 93 % of whom routinely perform THA. More than 50 % of respondents were fellowship trained. Most respondents (>87 %) in both years reported that they had used a modular implant, either when absolutely necessary (<5 % of time) or routinely (>50 % of time). From 2013 to 2014, the routine use of modular metal-metal junction implants decreased (head-neck, neck-stem, stem-body). In 2014, a higher percentage of surgeons reported concerns over debris and stem breakage and more chose ceramic heads over metal heads. Most respondents reported locking the femoral head with one or more forceful hits. When corrosion was noted on the taper during revision cases, most surgeons retained the femur while cleaning the taper with either a sponge or bovie scratch pad. Some respondents applied a ceramic head with a titanium sleeve between the damaged taper and the new femoral head; 94 % of respondents reported cleaning and drying the taper before head insertion. These results demonstrate that modular implants are widely used in THA. The number of surgeons routinely using modular implants remains high, making education regarding debris production and breakage with modular stems a necessity.

    Keywords:

    total hip arthroplasty, modular components, usage trends, technique


    Author Information:

    Ford, Marcus C.
    University of Tennessee-Campbell Clinic Dept. of Orthopaedic Surgery and Biomedical Engineering, Memphis, TN

    Harkess, John W.
    University of Tennessee-Campbell Clinic Dept. of Orthopaedic Surgery and Biomedical Engineering, Memphis, TN

    Mihalko, William M.
    University of Tennessee-Campbell Clinic Dept. of Orthopaedic Surgery and Biomedical Engineering, Memphis, TN


    Committee/Subcommittee: F04.22

    DOI: 10.1520/STP159120140140