SYMPOSIA PAPER Published: 01 July 2012
STP154520120003

Durability of Acrylic Sealants Applied to Joints of Autoclaved Lightweight Concrete Walls: Evaluation of Exposure Testing

Source

In Japan acrylic sealants are traditionally the sealant products of choice when specified for use between autoclaved lightweight concrete (ALC) panels. Although, in general terms, the mechanisms of the deterioration of acrylic sealants are well known its long-term durability to outdoor exposure has not, however, been fully investigated. The research described in this paper focuses on the change in the properties and deterioration of acrylic sealant products when exposed to outdoor testing. The two stage project consisted of (i) on-site investigations of deteriorated acrylic sealants that had been placed in external joints of ALC-clad buildings; and (ii) outdoor exposure testing of different types of acrylic sealant in three climate regions located in Japan. The results of the work from the first stage of the study revealed the following. Two-sided adhesion joint configurations installed in deep panel ALC cladding were more reliable than three-sided adhesion joints used for thin panel ALC cladding from the viewpoint of the durability of the sealed joint installed in actual buildings. Most fractures of the sealed joint could be characterized as failure in peel (or thin layer cohesive failures), in which the sealant ruptured at the interface with the ALC substrate to which it was applied. Additionally, in 47 of 62 locations surveyed, surface cracks were apparent on the coating that had been applied to protect the sealant. The second stage of the project focused on the degree of deterioration of coated and non-coated acrylic sealants subjected to outdoor exposure testing in a cold, a warm, and a subtropical climate. Results from this stage showed that aging of the sealant, as determined by the degree of surface cracking, expectedly depended on the local temperature and the respective degree of exposure to solar radiation. It was determined that the longer the exposure period, the lower the tensile performance of the acrylic sealants. The elongation of three-sided adhesive joint configurations after 5 years exposure testing decreased remarkably and their maximum elongation was less than 50 %. A significant number of sealed joints after 5 years ofexposure had ALC substrate failure.

Author Information

Miyauchi, Hiroyuki
305 764, Daejeon, KP
Lacasse, Michael, A.
National Research Council Canada, Institute for Research in Construction, Ottawa, CA
Enomoto, Noriyoshi
Japan Sealant Industry Association,, Tokyo, JP
Murata, Shigeki
ALC Association, Tokyo, JP
Tanaka, Kyoji
Tokyo Institute of Technology, Kanagawa, JP
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Developed by Committee: C24
Pages: 47–69
DOI: 10.1520/STP154520120003
ISBN-EB: 978-0-8031-7557-0