    Temperature Compensation and Correction in Detection of Oxygen Content Found in Glass Medicine Bottles Using Laser Wavelength Modulation Spectroscopy

    (Received 1 November 2017; accepted 21 March 2018)

    Published Online: 2018

    CODEN: JTEVAB

      Format Pages Price  
    PDF (542.24 KB) 11 $25   ADD TO CART

    Cite this document

    X Add email address send
    X
      .RIS For RefWorks, EndNote, ProCite, Reference Manager, Zoteo, and many others.   .DOCX For Microsoft Word



    Abstract

    Using laser wavelength modulation spectroscopy (LWMS), a rapid detection method to determine the oxygen contents in glass medicine bottles with an open single path and short optical distance was proposed. It is widely acknowledged that temperature changes influence the gas line strength, the full width at half maximum (FWHM) of absorption parameters, and the density of gas molecules. As a direct consequence, these factors affect the detection accuracy of gas concentrations. Two methods of temperature compensation and correction were proposed to address this problem: one method uses a theoretical compensation of scale factors based on the relationship between various parameters in the HITRAN 2012 database (Harvard-Smithsonian Center for Astrophysics, Cambridge, MA), and the second method uses the compensation of an experimental correction function based on the relationship between temperature and harmonic intensity measurements. Furthermore, the two methods were integrated into the regression equations for the peak value of the secondary harmonics and the gas concentration for quantitative predictions. At different temperatures (ranging from 276–316 K), glass medicine bottles with oxygen concentrations of 21 % were tested to obtain predictive values based on direct concentration evaluation by the two methods. The experimental results show that the predicated root mean square errors after theoretical and experimental correction are 0.0024 and 0.0058, respectively 80.33 % and 52.46 % less than that obtained through direct concentration evaluation. This validates the effectiveness of the two proposed methods, which can further improve the accuracy and stability for detecting gas concentration using LWMS.

    Author Information:

    Zhu, Gaofeng
    School of Information Science and Engineering, Central South University, Hunan,

    School of Information, Hunan University of Humanities, Science and Technology, Hunan,

    Zhu, Hongqiu
    School of Information Science and Engineering, Central South University, Hunan,

    Yang, Chunhua
    School of Information Science and Engineering, Central South University, Hunan,

    Gui, Weihua
    School of Information Science and Engineering, Central South University, Hunan,


    Stock #: JTE20170622

    ISSN:0090-3973

    DOI: 10.1520/JTE20170622

    Author
    Title Temperature Compensation and Correction in Detection of Oxygen Content Found in Glass Medicine Bottles Using Laser Wavelength Modulation Spectroscopy
    Symposium ,
    Committee G04