Journal Published Online: 25 February 2019
Volume 8, Issue 1

Activation Energy of Conduction for Use in Temperature Corrections on Electrical Measurements of Concrete

CODEN: ACEMF9

Abstract

The formation factor obtained through electrical resistivity measurements is becoming a popular method to determine transport properties of concrete. Resistivity measurements are dependent on multiple factors, including degree of saturation, pore solution conductivity, and temperature. The Arrhenius equation is used to correct electrical resistivity for temperature effects using an activation energy of conduction (Ea-cond). This parameter has been measured on a wide variety of materials, including pore solutions, pastes, mortars, and concretes (with a variety of saturation states). The reported values of Ea-cond typically range from 9 to 39 kJ/mol. This article examines the factors affecting Ea-cond in order to select an appropriate temperature correction. In this study, Ea-cond was determined from data measured on various concrete mixtures used in transportation infrastructure applications as well as extracted and simulated pore solutions. The Ea-cond of pore solutions remains relatively constant (an average value of 13.9 ± 1.5 kJ/mol) for typical pore solutions and was slightly lower than the Ea-cond of saturated specimens (an average value of 15.8 kJ/mol). It was found that Ea-cond increases as the degree of saturation of the specimen is reduced. Drying increases the ionic concentration of the fluid in the pores; however, this does not explain the changes in Ea-cond. The effects of drying were determined to be primarily due to a change in the volume of the conductive fluid film in the concrete and in the connectivity of the fluid-filled pores. While it is better to directly measure the Ea-cond of a concrete mixture, this is not always feasible or practical. In such cases, for pore solutions, a value of 13.9 kJ/mol can be used, and for saturated concretes, a value of 15.8 kJ/mol can be used. For concretes with a varying degree of saturation, the Ea-cond can be estimated using the developed equation.

Author Information

Coyle, Alex T.
School of Civil and Construction Engineering, Oregon State University, Corvallis, OR, USA
Spragg, Robert P.
SES Group & Associates LLC, Turner-Fairbank Highway Research Center, McLean, VA, USA
Suraneni, Prannoy
Department of Civil, Architectural, and Environmental Engineering, University of Miami, Coral Gables, FL, USA
Amirkhanian, Armen N.
Department of Civil, Construction and Environmental Engineering, University of Alabama, Tuscaloosa, AL, USA
Tsui-Chang, Marisol
School of Civil and Construction Engineering, Oregon State University, Corvallis, OR, USA
Weiss, William Jason
School of Civil and Construction Engineering, Oregon State University, Corvallis, OR, USA
Pages: 13
Price: $25.00
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Stock #: ACEM20180045
ISSN: 2379-1357
DOI: 10.1520/ACEM20180045