Work Item
ASTM WK76431

New Test Method for Exoskeleton Use: Stairs

1. Scope

1.1 Purpose: 1.1.1 The purpose of this test method, as a part of a suite of exoskeleton use test methods, is to quantitatively evaluate an exoskeleton (see Terminology F3323) safety (see section 1.4) and/or performance for ascending/descending stairs. 1.1.2 Exoskeletons shall possess a certain set of allowable exoskeleton user movement capabilities, including user-motion adaptability, to suit operations such as: industrial/occupational, military, response, medical or recreational. Environments in these typical sectors often pose constraints to exoskeleton user movement to various degrees. Being able to ascend/descend stairs, as intended by the user or test requestor, while using an exoskeleton is essential for exoskeleton deployment for a variety of tasks (e.g., ascending/descending stairs, ramps, hills). This test method specifies test setup, procedure, and recording to standardize this stairs task for testing exoskeleton user movement. 1.1.3 Exoskeletons shall be able to handle many types of task and terrain complexities. The required movement capabilities include, for example: walking, running, crawling, climbing, traversing gaps, hurdles, stairs, slopes, various types of floor surfaces or terrains, and confined spaces. Standard test methods are required to evaluate whether or not exoskeletons meet these requirements. 1.1.4 ASTM Subcommittee F48.03 develops and maintains international standards for task performance and environmental considerations that includes but is not limited to, standards for safety, quality and efficiency. This subcommittee aims to develop standards for any exoskeleton applications as exemplified as in 1.1.2. The F48.03 test suite, consists of a set of test methods for evaluating exoskeleton capability requirements. This stairs test method is a part of the test suite. The setup, procedure, and apparatuses associated with the test methods challenge specific exoskeleton capabilities in repeatable ways to facilitate comparison of different exoskeleton models or exoskeleton capabilities to tasks. 1.1.5 The test methods quantify elemental exoskeleton use capabilities necessary for sector applications listed in 1.1.2 and perhaps others. As such, users of this standard should use either the entire suite or a subset based on their particular requirements. Users are also allowed to weight particular test methods or particular metrics within a test method differently based on their specific requirements. The testing results should collectively represent an exoskeletons overall safety and/or performance as required for the task. These performance data can be used: to guide procurement specifications, for acceptance testing, and for training to use exoskeletons intended for specified applications. NOTE 1Additional test methods within the suite are anticipated to be developed to address additional exoskeleton capability requirements, including newly identified requirements and even for new application domains. 1.2 Exoskeleton The exoskeleton shall be used as intended by the manufacturer to perform the test described in this test method. If the exoskeleton is not designed for stair use and the test requestor intends to use the exoskeleton to perform a stair test (e.g., for research, development of stair-capable use by a manufacturer, stair training as in medical rehabilitation applications), the test method may be used and appropriate manufacturer approvals should be sought. 1.3 Performing LocationThis test method shall be performed in a testing laboratory or the field where the specified apparatus and environmental conditions are implemented. 1.4 UnitsThe values stated in SI units are to be regarded as the standard. The values given in parentheses are not precise mathematical conversions to inch-pound units. They are close approximate equivalents for the purpose of specifying material dimensions or quantities that are readily available to avoid excessive fabrication costs of test apparatuses while maintaining repeatability and reproducibility of the test method results. These values given in parentheses are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Keywords

exoskeleton; exosuit; stairs; industrial/occupational; military; response; medical; recreational; movement

Rationale

This test method is part of a suite of exoskeleton test methods allowing a variety of selectable areas to measure safety and performance of exoskeletons.

The title and scope are in draft form and are under development within this ASTM Committee.

Details

Developed by Subcommittee: F48.03

Committee: F48

Staff Manager: Nora Nimmerichter

Work Item Status

Date Initiated: 04-05-2021

Technical Contact: Roger Bostelman

Item: 007

Ballot: F48 (22-01)

Status: Withdrawn From Balloting

Item: 001

Ballot: F48 (22-02)

Status: In Balloting