ASTM WK69909

    Revision of C1861 - 18 Standard Specification for Lathing and Furring Accessories, and Fasteners, for Interior and Exterior Portland Cement-Based Plaster

    (What is a Work Item?)

    Active Standard: C1861 - 18

    Developed by Subcommittee: C11.02 | Committee C11 | Contact Staff Manager



    WK69909


    Keywords

    adhesive; cement plaster; casing bead; cold-rolled channel furring; control joint; corner reinforcement; drainage screed; expansion joint; fastener; furring accessory; lathing accessory; nail; screw; staple; weep screed;;

    Rationale

    Rationale: Current Table 3 minimum fastener lengths indicated are for stucco assemblies without additional components such as foam plastic insulation and drainage mats. Table 3 does not state requirements for the additional fastener lengths needed to accommodate these additional components. 1.Adds new Footnote A wording: When additional components such as CI and drainmat are included in the stucco assembly, proposed additional wording is broad enough to require use of either prescriptive fasteners compliant with the local code (such as in IBC Chapter 26 CI fastener tables), or engineering evaluation and approval of Authority Having Jursisdiction.

    Citing ASTM Standards
    Back to Top
    Work Item Status

    Date Initiated:
    09-12-2019

    Technical Contact:
    Jeff Bowlsby

    Item:
    004

    Ballot:
    C11.02 (19-07)

    Status:
    Negative Votes Need Resolution