Developed by Subcommittee: C13.07 | Committee C13 | Contact Staff Manager
Keywords
Rationale
Clarification on Figure 3: Reinforcing details shown in Figures 3 through 14 need to be clarified in terms of reinforcing configurations and dimensional limitations. In a previous ballot, a proposal to fix an apparent error in the figures caused confusion regarding requirements for extension length of the inside cage (As2 and As3). This ballot serves to provide additional details to cover known industry practices and clarify requirements associated with location and extension of the As2 / As3 cages as well as As4. For a rigid frame member, As2 As3 and As4 are in compression in the installed condition at the ends of a member and as such do not require development length past the face of the wall. Various cage construction practices are shown based on known production practices and limiting dimensions are shown to meet the needs of these production practices and the requirements of the design.
Back to TopDate Initiated:
07-12-2019
Technical Contact:
William Washabaugh
Item:
023
Ballot:
C13 (19-04)
Status:
Ballot Item Approved as C1433-2020
and Pending Publication