ASTM WK69079

    Revision of C1433 - 16b Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers

    (What is a Work Item?)

    Active Standard: C1433 - 19

    Developed by Subcommittee: C13.07 | Committee C13 | Contact Staff Manager



    WK69079


    Keywords


    Rationale

    Clarification on Figure 3: Reinforcing details shown in Figures 3 through 14 need to be clarified in terms of reinforcing configurations and dimensional limitations. In a previous ballot, a proposal to fix an apparent error in the figures caused confusion regarding requirements for extension length of the inside cage (As2 and As3). This ballot serves to provide additional details to cover known industry practices and clarify requirements associated with location and extension of the As2 / As3 cages as well as As4. For a rigid frame member, As2 As3 and As4 are in compression in the installed condition at the ends of a member and as such do not require development length past the face of the wall. Various cage construction practices are shown based on known production practices and limiting dimensions are shown to meet the needs of these production practices and the requirements of the design.

    Citing ASTM Standards
    Back to Top
    Work Item Status

    Date Initiated:
    07-12-2019

    Technical Contact:
    William Washabaugh

    Item:
    023

    Ballot:
    C13 (19-04)

    Status:
    Negative Votes Need Resolution