Standard Historical Last Updated: Aug 16, 2017 Track Document
ASTM E498-95(2000)

Standard Test Methods for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode

Standard Test Methods for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode E0498-95R00 ASTM|E0498-95R00|en-US Standard Test Methods for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode Standard new BOS Vol. 03.03 Committee E07
$ 66.00 In stock

Scope

1.1 These test methods cover procedures for testing and locating the sources of gas leaking at the rate of 4.5 X 10 -14 mol/s (1 X 10 -9 Std cm3/s) or greater. The test may be conducted on any object to be tested that can be evacuated and to the other side of which helium or other tracer gas may be applied.

1.2 Three test methods are described:

1.2.1 Test Method A -For the object under test capable of being evacuated, but having no inherent pumping capability.

1.2.2 Test Method B -For the object under test with integral pumping capability.

1.2.3 Test Method C -For the object under test as in Test Method B, in which the vacuum pumps of the object under test replace those normally used in the leak detector.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific hazard statement can be found in 19.2.

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 03.03
Developed by Subcommittee: E07.08
Pages: 4
DOI: 10.1520/E0498-95R00
ICS Code: 19.100