Standard Historical Last Updated: Aug 16, 2017 Track Document
ASTM E1214-87(2000)

Standard Guide for Use of Melt Wire Temperature Monitors for Reactor Vessel Surveillance, E706(IIIE)

Standard Guide for Use of Melt Wire Temperature Monitors for Reactor Vessel Surveillance, E706(IIIE) E1214-87R00 ASTM|E1214-87R00|en-US Standard Guide for Use of Melt Wire Temperature Monitors for Reactor Vessel Surveillance, E706(IIIE) Standard new BOS Vol. 12.02 Committee E10
$ 66.00 In stock

Scope

1.1 This guide describes the application of melt wire temperature monitors and their use for reactor vessel surveillance of light-water power reactors as called for in Practice E185.

1.2 The purpose of this guide is to recommend the selection and use of the common melt wire technique where the correspondence between melting temperature and composition of different alloys is used as a passive temperature monitor. Guidelines are provided for the selection and calibration of monitor materials; design, fabrication, and assembly of monitor and container; post-irradiation examinations; interpretation of the results; and estimation of uncertainties.

1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (See Note.)

Price:
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Book of Standards Volume: 12.02
Developed by Subcommittee: E10.02
Pages: 3
DOI: 10.1520/E1214-87R00
ICS Code: 27.120.20