ASTM C1567-08

    Standard Test Method for Determining the Potential Alkali-Silica Reactivity of Combinations of Cementitious Materials and Aggregate (Accelerated Mortar-Bar Method)


      Format Pages Price  
    PDF 6 $54.00   ADD TO CART


    1. Scope

    1.1 This test method permits detection within 16 days of the potential for deleterious alkali-silica reaction of combinations of cementitious materials and aggregate in mortar bars. The cementitious materials are composed of various proportions of hydraulic cement, pozzolans and ground granulated blast-furnace slag.

    1.2 The test results are only valid for the specific combinations of pozzolan, slag, and reactive aggregates tested.

    1.3 This test is not suitable for evaluating the potential for deleterious reaction of combinations of hydraulic cement and aggregate (that is, in the absence of pozzolans or ground granulated blast-furnace slag).

    1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in the section on Reagents.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    C109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)

    C125 Terminology Relating to Concrete and Concrete Aggregates

    C127 Test Method for Density, Relative Density (Specific Gravity), and Absorption of Coarse Aggregate

    C128 Test Method for Density, Relative Density (Specific Gravity), and Absorption of Fine Aggregate

    C150 Specification for Portland Cement

    C151 Test Method for Autoclave Expansion of Hydraulic Cement

    C305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency

    C490 Practice for Use of Apparatus for the Determination of Length Change of Hardened Cement Paste, Mortar, and Concrete

    C494/C494M Specification for Chemical Admixtures for Concrete

    C511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes

    C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete

    C670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials

    C989 Specification for Slag Cement for Use in Concrete and Mortars

    C1240 Specification for Silica Fume Used in Cementitious Mixtures

    C1260 Test Method for Potential Alkali Reactivity of Aggregates (Mortar-Bar Method)

    C1293 Test Method for Determination of Length Change of Concrete Due to Alkali-Silica Reaction

    C1437 Test Method for Flow of Hydraulic Cement Mortar

    D1193 Specification for Reagent Water

    E11 Specification for Woven Wire Test Sieve Cloth and Test Sieves


    ICS Code

    ICS Number Code 91.100.30 (Concrete and concrete products)

    Referencing This Standard
    Link Here
    Link to Active (This link will always route to the current Active version of the standard.)

    DOI: 10.1520/C1567-08

    Citation Format

    ASTM C1567-08, Standard Test Method for Determining the Potential Alkali-Silica Reactivity of Combinations of Cementitious Materials and Aggregate (Accelerated Mortar-Bar Method), ASTM International, West Conshohocken, PA, 2008, www.astm.org