SUPERSEDED (click for Active standard)
  | Format | Pages | Price |   |
![]() |
6 | $62.00 | ![]() |
Active (view current version of standard)
1. Scope
1.1 This test method covers the effects of repeated insertion and withdrawal of separable electrical connectors which are harmful to the electrical performance of the connector.
1.2 This test method is limited to electrical connectors designed for use in applications where the current through any one connection in the connector does not exceed 5 A, and where the connector may be separated a number of times during the life of the connector.
1.3 This test method is limited to electrical connectors intended for use in air ambients where the operating temperature is less than 65°C.
1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
B539 Test Methods for Measuring Resistance of Electrical Connections (Static Contacts)
Military Standard
MIL-STD-1344AUNSPSC Code
UNSPSC Code
Link Here | |||
Link to Active (This link will always route to the current Active version of the standard.) | |||
DOI: 10.1520/B0794-97
Citation Format
ASTM B794-97, Standard Test Method for Durability Wear Testing of Separable Electrical Connector Systems Using Electrical Resistance Measurements, ASTM International, West Conshohocken, PA, 1997, www.astm.org