D21 POLISHES D26 HALOGENATED ORGANIC SOLVENTS AND FIRE EXTINGUISHING AGENTS D33 PROTECTIVE COATING AND LINING WORK FOR POWER GENERATION FACILITIES E05 FIRE STANDARDS E27 HAZARD POTENTIAL OF CHEMICALS E30 FORENSIC SCIENCES E34 OCCUPATIONAL HEALTH AND SAFETY E35 PESTICIDES, ANTIMICROBIALS, AND ALTERNATIVE CONTROL AGENTS E52 FORENSIC PSYCHOPHYSIOLOGY E54 HOMELAND SECURITY APPLICATIONS E58 FORENSIC ENGINEERING F06 RESILIENT FLOOR COVERINGS F08 SPORTS EQUIPMENT, PLAYING SURFACES, AND FACILITIES F10 LIVESTOCK, MEAT, AND POULTRY EVALUATION SYSTEMS F12 SECURITY SYSTEMS AND EQUIPMENT F13 PEDESTRIAN/WALKWAY SAFETY AND FOOTWEAR F15 CONSUMER PRODUCTS F18 ELECTRICAL PROTECTIVE EQUIPMENT FOR WORKERS F23 PERSONAL PROTECTIVE CLOTHING AND EQUIPMENT F26 FOOD SERVICE EQUIPMENT F32 SEARCH AND RESCUE F33 DETENTION AND CORRECTIONAL FACILITIES G04 COMPATIBILITY AND SENSITIVITY OF MATERIALS IN OXYGEN ENRICHED ATMOSPHERES B01 ELECTRICAL CONDUCTORS C26 NUCLEAR FUEL CYCLE D02 PETROLEUM PRODUCTS, LIQUID FUELS, AND LUBRICANTS D03 GASEOUS FUELS D05 COAL AND COKE D19 WATER D27 ELECTRICAL INSULATING LIQUIDS AND GASES D33 PROTECTIVE COATING AND LINING WORK FOR POWER GENERATION FACILITIES E10 NUCLEAR TECHNOLOGY AND APPLICATIONS E44 SOLAR, GEOTHERMAL AND OTHER ALTERNATIVE ENERGY SOURCES E48 BIOENERGY AND INDUSTRIAL CHEMICALS FROM BIOMASS E11 QUALITY AND STATISTICS E36 ACCREDITATION & CERTIFICATION E43 SI PRACTICE E55 MANUFACTURE OF PHARMACEUTICAL PRODUCTS E56 NANOTECHNOLOGY F42 ADDITIVE MANUFACTURING TECHNOLOGIES
Bookmark and Share

InFocus

InFocus

Flash Point Determination

A New ASTM Manual Guides Its Practice

Accurate equipment means accurate test results in many areas — including flash point — and a new reference from ASTM International covers preparing, maintaining and checking apparatus for such testing. ASTM Manual 72, The Practice of Flash Point Determination: A Laboratory Resource, addresses equipment, methods and more.

As introduced in Manual 72, “Flash point is the lowest temperature of a liquid at which sufficient vapor is generated to create a flammable mixture with air in the presence of an ignition source.” Flash point is used to classify a liquid material as combustible or flammable; in that way it helps define product quality. And Manual 72 provides laboratory technicians as well as supervisors, and manufacturing and marketing personnel, with information about various aspects of flash point determination.

The nine chapters and five appendixes in Manual 72 address the practical significance and use of flash point, the terminologies used in flash point determination, sample handling and specimen preparation, test apparatus and the various test methods of determining flash point. Editor Rey Montemayor, Ph.D., an ASTM International fellow and long-time member of Committee D02 on Petroleum Products and Lubricants, says that Manual 72 details flash point testing from the time a sample arrives in a laboratory to reporting the test result values. He adds that Manual 72 offers more than other books on the topic: “The information on how sample viscosity affects the flash point, as well as flash point masking, are topics which have been discussed sparingly in other works in this area.”

In addition to the attention paid to the proper preparation and use of the apparatus, Manual 72 addresses the precision of various flash point test methods as well as how precision information is obtained. The work also contains information comparing features of different flash point methods, which furthers the understanding of flash point testing.

Specifically, the manual chapters cover:

  • Significance and current use of the flash point test methods;
  • Explanation and definition of terms;
  • Flash point apparatus and auxiliary equipment;
  • Sampling and test specimens for flash point determination;
  • Preparation, verification and maintenance of apparatus;
  • Procedures, corrections and reporting;
  • Precision of flash point test methods; and
  • Flash point relationships with other volatility properties.

Laboratory operators and technicians who perform flash point tests on various liquid materials will find the manual a useful reference in their work; supervisors and managers should find the flash point test precision details helpful in interpreting results for use by others in the manufacturing and marketing of petroleum products, lubricants, solvents and other volatile liquids or mixtures.

Montemayor notes that the appendixes included in the manual are particularly informative, extending the information about flash point testing as it relates to manufacturing products that could be flammable or combustible. The manual provides a resource to laboratories in satisfying performance specifications for liquid fuels and materials as well as conforming to government safety standards for storage, use and transportation of potentially flammable or combustible materials.

This article appears in the issue of Standardization News.