ASTM F744M - 10

    Standard Test Method for Measuring Dose Rate Threshold for Upset of Digital Integrated Circuits [Metric]

    Active Standard ASTM F744M | Developed by Subcommittee: F01.11

    Book of Standards Volume: 10.04


      Format Pages Price  
    PDF 7 $43.00   ADD TO CART
    Hardcopy (shipping and handling) 7 $43.00   ADD TO CART
    Standard + Redline PDF Bundle 14 $51.60   ADD TO CART


    Significance and Use

    Digital integrated circuits are specified to operate with their inputs and outputs in either a logical 1 or a logical 0 state. The occurrence of signals having voltage levels not meeting the specifications of either of these levels (an upset condition) may cause the generation and propagation of erroneous data in a digital system.

    Knowledge of the radiation dose rate that causes upset in digital integrated circuits is essential for the design, production, and maintenance of electronic systems that are required to operate in the presence of pulsed radiation environments.

    1. Scope

    1.1 This test method covers the measurement of the threshold level of radiation dose rate that causes upset in digital integrated circuits under static operating conditions. The radiation source is either a flash X-ray machine (FXR) or an electron linear accelerator (LINAC).

    1.2 The precision of the measurement depends on the homogeneity of the radiation field and on the precision of the radiation dosimetry and the recording instrumentation.

    1.3 The test may be destructive either for further tests or for purposes other than this test if the integrated circuit being tested absorbs a total radiation dose exceeding some predetermined level. Because this level depends both on the kind of integrated circuit and on the application, a specific value must be agreed upon by the parties to the test (6.8).

    1.4 Setup, calibration, and test circuit evaluation procedures are included in this test method.

    1.5 Procedures for lot qualification and sampling are not included in this test method.

    1.6 Because of the variability of the response of different device types, the initial dose rate for any specific test is not given in this test method but must be agreed upon by the parties to the test.

    1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    E665 Practice for Determining Absorbed Dose Versus Depth in Materials Exposed to the X-Ray Output of Flash X-Ray Machines (Withdrawn 2000) Withdrawn. The last approved version of this historical standard is referenced on www.astm.org.

    E666 Practice for Calculating Absorbed Dose From Gamma or X Radiation

    E668 Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices

    E1894 Guide for Selecting Dosimetry Systems for Application in Pulsed X-Ray Sources

    F526 Test Method for Using Calorimeters for Total Dose Measurements in Pulsed Linear Accelerator or Flash X-ray Machines


    UNSPSC Code

    UNSPSC Code


    DOI: 10.1520/F0744M-10

    ASTM International is a member of CrossRef.

    ASTM F744M

    Citing ASTM Standards
    Back to Top