ASTM F2418 - 12 Standard Specification for Polypropylene (PP) Corrugated Wall Stormwater Collection Chambers


Active Standard ASTM F2418 Developed by Subcommittee: F17.65 |Book of Standards Volume: 08.04

more info 7 pages $ 41.00
more info 7 pages $ 41.00
why redline? 14 pages $ 49.20

Historical (view previous versions of standard) ASTM License Agreement Shipping & Handling

More F17.65 Standards Related Products
Copyright/Permissions Standard References

ASTM F2418

Abstract

This specification covers requirements, test methods, materials, and marking for polypropylene (PP), open bottom, buried chambers of corrugated wall construction used for collection, detention, and retention of stormwater runoff. Applications include commercial, residential, agricultural, and highway drainage, including installation under parking lots and roadways. Chambers are produced in arch shapes with dimensions based on chamber rise, chamber span, and wall stiffness. They are manufactured with integral feet that provide base support. They may include perforations to enhance water flow and must meet test requirements for arch stiffness, flattening, and accelerated weathering. The successful performance of the product depends upon the type and depth of bedding and backfill, and care in installation. This specification includes requirements for the manufacturer to provide chamber installation instructions to the purchaser.

This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope

1.1 This specification covers requirements, test methods, materials, and marking for polypropylene (PP), open bottom, buried chambers of corrugated wall construction used for collection, detention, and retention of stormwater runoff. Applications include commercial, residential, agricultural, and highway drainage, including installation under parking lots and roadways.

1.2 Chambers are produced in arch shapes with dimensions based on chamber rise, chamber span, and wall stiffness. Chambers are manufactured with integral feet that provide base support. Chambers may include perforations to enhance water flow. Chambers must meet test requirements for arch stiffness, flattening, and accelerated weathering.

1.3 Analysis and experience have shown that the successful performance of this product depends upon the type and depth of bedding and backfill, and care in installation. This specification includes requirements for the manufacturer to provide chamber installation instructions to the purchaser.

1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5 This standard does not purport to address water quality issues or hydraulic performance requirements associated with its use. It is the responsibility of the user to ensure that appropriate engineering analysis is performed to evaluate the water quality issues and hydraulic performance requirements for each installation.

1.6 The following safety hazards caveat pertains only to the test method portion, Section 6, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

D256 Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics

D618 Practice for Conditioning Plastics for Testing

D638 Test Method for Tensile Properties of Plastics

D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials

D1600 Terminology for Abbreviated Terms Relating to Plastics

D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings

D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading

D2990 Test Methods for Tensile, Compressive, and Flexural Creep and Creep-Rupture of Plastics

D4101 Specification for Polypropylene Injection and Extrusion Materials

D4329 Practice for Fluorescent UV Exposure of Plastics

D6992 Test Method for Accelerated Tensile Creep and Creep-Rupture of Geosynthetic Materials Based on Time-Temperature Superposition Using the Stepped Isothermal Method

F412 Terminology Relating to Plastic Piping Systems

F2787 Practice for Structural Design of Thermoplastic Corrugated Wall Stormwater Collection Chambers



Keywords

ASC; arch stiffness constant; chamber; corrugated wall; detention; drainage; end cap; exfiltration; first flush; infiltration; PP; polypropylene; retention; stormwater; sub-surface; thermoplastic; underground; Arch stiffness constant (ASC); Corrugated wall; Polypropylene (PP); Stormwater



ICS Code

ICS Number Code 83.140.01 (Rubber and plastic products in general)