ASTM F2255 - 05(2010)

    Standard Test Method for Strength Properties of Tissue Adhesives in Lap-Shear by Tension Loading

    Active Standard ASTM F2255 | Developed by Subcommittee: F04.15

    Book of Standards Volume: 13.01


      Format Pages Price  
    PDF 6 $42.00   ADD TO CART
    Hardcopy (shipping and handling) 6 $42.00   ADD TO CART
    Standard + Redline PDF Bundle 12 $50.40   ADD TO CART


    Significance and Use

    Materials and devices that function at least in part by adhering to living tissues are finding increasing use in surgical procedures either as adjuncts to sutures and staples, or as frank replacements for those devices in a wide variety of medical procedures. While the nature and magnitude of the forces involved varies greatly with indication and with patient specific circumstances, all uses involve to some extent the ability of the material to resist imposed mechanical forces. Therefore, the mechanical properties of the materials, and in particular the adhesive properties, are important parameters in evaluating their fitness for use. In addition, the mechanical properties of a given adhesive composition can provide a useful means of determining product consistency for quality control, or as a means for determining the effects of various surface treatments on the substrate prior to use of the device.

    The complexity and variety of individual applications for tissue adhesive devices, even within a single indicated use (surgical procedure) is such that the results of a single-lap-shear test are not suitable for determining allowable design stresses without thorough analysis and understanding of the application and adhesive behaviors.

    This test method may be used for comparing adhesives or bonding processes for susceptibility to fatigue and environmental changes, but such comparisons must be made with great caution since different adhesives may respond differently to varying conditions.

    1. Scope

    1.1 This test method is intended to provide a means for comparison of the adhesive strengths of tissue adhesives intended for use as surgical adhesives or sealants, or both, on soft tissue. With the appropriate choice of substrate, it may also be used for purposes of quality control in the manufacture of tissue adhesive based medical devices.

    1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    D907 Terminology of Adhesives

    E4 Practices for Force Verification of Testing Machines

    American Association of Tissue Banks Standards

    StandardsforTissueBa


    ICS Code

    ICS Number Code 59.080.01 (Textiles in general); 83.180 (Adhesives)

    UNSPSC Code

    UNSPSC Code 42312005(Medical adhesives or glues for skin closure)


    DOI: 10.1520/F2255-05R10

    ASTM International is a member of CrossRef.

    ASTM F2255